Radiation Shield Wiring

The radiation shield houses integrated environmental sensors to ensure accurate readings:

  • Temperature: Monitored via the SHT31D & MCP9808 which measures ambient air temperature using a precision thermistor.

  • Relative Humidity: Detected by the SHT31D, which calculates moisture levels via capacitance changes in a polymer layer.

  • Atmospheric Pressure: Measured by the BMP390, a piezoresistive sensor that converts pressure changes into digital signals.

Wiring: All three sensors connect via I2C (shared SDA/SCL lines) to minimize wiring complexity. The radiation shield’s passive ventilation design protects sensors from direct sunlight, precipitation, and debris while maintaining airflow for precision.

Instruction Slides

BMP390 Data Sheet: https://drive.google.com/file/d/1SPz26aSSjAcI60IiRl2aWFNGYPNsM4U1/view?usp=sharing SHT31D Data Sheet: https://drive.google.com/file/d/16DI1sN1-oBiDy-r1EkRpwLqHehM3LIvt/view?usp=sharing MCP9808 Data Sheet: https://drive.google.com/file/d/1RvLQRoUSQnQXanRsuRBg3e4OvptU6nNu/view?usp=sharing